East London · Homes, landlords and small commercial

A certificate,
not just an invoice.

Electrical work on a home should end with a certificate and test results, and notifiable work should be registered with the council. An invoice on its own proves nothing to a buyer or an insurer.

  • 2024trading since
  • UKregistered company
  • Part Pnotified
  • BS 7671tested
A JOB · HOW IT WORKS Before we start 50 % complete Free written quote Scheme registration shown Tested before leaving Certificate issued Quote Free, no obligation Next step « We reply within 24 hours »
What we do

Four services, all tested and certified

Registered with a competent person scheme, so notifiable work is self-certified and the council notified.

How it works

How we work

Inspect before quoting, test before leaving, code honestly, and issue the certificate every time.

Free written quote

After looking, not over the phone.

Scheme registration shown

So notifiable work can be self-certified.

Tested before we leave

Results recorded, not assumed.

Certificate issued

EIC, minor works or EICR as applies.

Working together

Ways to book

Quoted in writing after an inspection. Certificates are included, not charged as an extra.

EICR

The five-yearly report landlords must hold.

  • Every circuit tested
  • Results recorded in full
  • Coded honestly, C1 and C2 flagged
  • Report issued promptly
  • Remedial work quoted separately
Book an EICR

Additions & EV

Extra circuits, fault finding and charge points.

  • Faults located by testing
  • Quoted before repair
  • EV supply assessed first
  • Told when an upgrade is needed
  • Certificate issued for the work
Talk it through

Every engagement is quoted after a free consultation. No subscription.

A typical week Mon Survey Tue Quote Wed Install Thu Test Fri Certify
How we work

East London electricians, registered and certified

TN & A Electrical Service Ltd is a private limited company registered in England and Wales under company number 15606186, incorporated in March 2024, with its registered office at 98 Commercial Road, London E1 1NU. We work to BS 7671 and are registered with a government-authorised competent person scheme under [COMPETENT PERSON SCHEME REGISTRATION NUMBER].

Two things worth insisting on from any electrician. Notifiable work in a home must be registered — through a competent person scheme or with building control — and you should receive a compliance certificate, because without it a buyer's solicitor or an insurer has nothing to rely on. And an EICR records condition on the day: it is not a warranty against future faults, and a report with a C1 or C2 cannot honestly be marked satisfactory. We do not carry out gas work, which needs a Gas Safe registered engineer.

See how we work

Frequently asked

The questions we get most

How often does a rented property need an EICR?

At least every five years in England, with the report held and given to tenants and, on request, the local authority. That has been the law since 2020 and it is enforced by councils.

My EICR came back unsatisfactory. Is that normal?

It is common in older housing, and it means something coded C1 or C2 was found — danger or potential danger. We will not mark a report satisfactory where one applies, and the remedial work is quoted separately so you can compare prices.

Do I need the council involved for a new socket?

Some work is notifiable and some is not. Where it is, our scheme registration lets us self-certify and notify, and you get a compliance certificate. Ask any electrician whether they can do that.

Can you just replace the tripping breaker?

Not without finding why it trips. A breaker doing its job is a symptom; swapping it removes the protection and leaves the fault. We test to locate it first.

Can I have an EV charger on my existing supply?

Often yes, and sometimes not. A charge point draws a sustained load, so the main fuse, board and earthing all need assessing first. We will tell you honestly if an upgrade is needed before you order a car charger.

Do you do gas as well?

No. Gas work requires a Gas Safe registered engineer and we are electricians. We will coordinate rather than take it on.

Need an EICR or a board replaced?

A free quote after we have looked, with the certificate included.